{"product_id":"1761-cbl-pm02-allen-bradley-micrologix-cable","title":"1761-CBL-PM02 |  Allen Bradley | MicroLogix Cable","description":"\u003cp data-path-to-node=\"0\"\u003e\u003cstrong\u003eAllen Bradley 1761-CBL-PM02 MicroLogix Programming Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eAllen Bradley 1761-CBL-PM02\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"1\" data-index-in-node=\"55\"\u003e1761-CBL-PM02\u003c\/b\u003e Communication Cable, operates as a dedicated hardware component for programming and data serial transmission within MicroLogix and PanelView PLC networks.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable data-path-to-node=\"3\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,1,1,0\"\u003e1761-CBL-PM02\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,2,1,0\"\u003eAllen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,3,0,0\"\u003eSeries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,3,1,0\"\u003eMicroLogix Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,4,0,0\"\u003eProduct Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,4,1,0\"\u003eProgramming and Communication Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,5,0,0\"\u003eCable Length\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,5,1,0\"\u003e2.0 meters (6.5 feet)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,6,0,0\"\u003eController Side Connector\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,6,1,0\"\u003e8-pin Mini-DIN Male\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,7,0,0\"\u003eTerminal Side Connector\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,7,1,0\"\u003e9-pin D-Shell (DB-9) Female\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,8,0,0\"\u003eCommunication Protocol\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,8,1,0\"\u003eRS-232 DF1 Full Duplex \/ DH-485\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,9,0,0\"\u003eNet Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,9,1,0\"\u003e0.15 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,10,0,0\"\u003eShipping Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,10,1,0\"\u003e0.5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,11,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,11,1,0\"\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"4\"\u003e\u003cstrong\u003eBackplane Communication and Execution Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe Allen Bradley 1761-CBL-PM02 cable provides physical-layer serial connectivity between PC programming workstations (running RSLogix 500) and MicroLogix 1000, 1100, 1200, 1400, and 1500 controllers. Built to maintain strict backplane bus communication velocity Licences and deterministic baud rates (up to 38.4 kbps), the cable assembly utilizes high-density copper conductors with foil and braid shielding. This construction suppresses signal degradation and cross-talk during program download routines and firmware flash compatibility updates in high-EMI panel environments.\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eQ: Which Allen Bradley controllers are compatible with the 1761-CBL-PM02 interface cable?\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eA: The cable connects directly to the 8-pin Mini-DIN channel 0 port on MicroLogix 1000, 1100, 1200, 1400, and 1500 controllers, as well as select PanelView operator panels.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eQ: Can this cable be used with modern laptops that only have USB ports?\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eA: Yes, but it requires a industrial-grade USB-to-RS232 serial converter (such as the 9300-USBCS) paired with the DB-9 female end of the 1761-CBL-PM02.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003eInspect the 8-pin Mini-DIN connector pins for proper alignment prior to plugging into the controller interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003eAlign the keyway of the Mini-DIN plug with the channel 0 port on the MicroLogix CPU and push gently until seated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003eConnect the 9-pin DB-9 female connector to the host computer serial port and tighten retention screws to secure grounding contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003eRoute the cable away from high-voltage AC motor drives and power lines to eliminate signal noise during online monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003eVerify serial port configuration settings (Baud Rate, Parity, Stop Bits) in RSLinx Classic software to establish active communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43836129706058,"sku":"1761-CBL-PM02","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/1761-CBL-AS03_3.png?v=1761208885","url":"https:\/\/www.topbrandsplc.com\/products\/1761-cbl-pm02-allen-bradley-micrologix-cable","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}