{"product_id":"22f-a2p5n103-allen-bradley-powerflex-4m-ac-drive","title":"22F-A2P5N103 | Allen Bradley | PowerFlex 4M AC Drive","description":"\u003ch1\u003e\u003cspan class=\"citation-29 citation-end-29\"\u003eAllen-Bradley 22F-A2P5N103 PowerFlex 4M AC Drive\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan class=\"citation-28\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 22F-A2P5N103\u003c\/strong\u003e\u003cspan class=\"citation-28\"\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e22F-A2P5N103\u003c\/strong\u003e\u003cspan class=\"citation-28 citation-end-28\"\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive, operates as a dedicated hardware component for feed-through motor speed modulation and pulse-width modulated (PWM) inverter control within PowerFlex 4M automation networks.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22F-A2P5N103\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ Multi-Region\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.6 kg (3.5 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e72.0 x 174.0 x 136.0 mm (2.83 x 6.85 x 5.35 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 deg C to 50 deg C (14 deg F to 122 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.37 kW (0.5 HP) power output rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 VAC, 1-Phase (200-240 VAC range, 50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 230 VAC, 3-Phase variable frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ NEMA Open Type (Frame Size A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegral LED display with fixed digital keypad\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEmbedded I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Discrete Inputs (24 VDC), 2 Analog Inputs (0-10V, 4-20mA), 1 Relay Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Backplane \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 4M architecture integrates high-density drive control circuitry with feed-through wiring topology, simplifying physical terminal management inside compact enclosures. Internal microprocessor-driven pulse-width modulation (PWM) algorithms execute deterministic speed control across 3-phase induction motors.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-27 citation-end-27\"\u003eDigital input density is optimized via DIP-switch selectable 24 VDC Sink or Source logic modes, ensuring millisecond-level feedback response over Modbus RTU serial networks without increasing physical enclosure volume.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 22F-A2P5N103 drive feature an embedded dynamic braking transistor (IGBT)?\u003c\/p\u003e\n\u003cp\u003eA: No.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-26 citation-end-26\"\u003eThe '3' suffix code specifies a base drive configuration constructed without an internal dynamic braking IGBT.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eQ: How are analog input references wired and controlled on the physical terminal block?\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-25 citation-end-25\"\u003eA: The drive provides two isolated analog input terminals (0 to 10 VDC voltage and 4 to 20 mA current), allowing simultaneous connection of external speed potentiometers or process controllers.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eQ: What mounting restrictions apply to the Frame Size A IP20 enclosure?\u003c\/p\u003e\n\u003cp\u003eA: The unit is designed for direct DIN-rail or panel mounting within protective industrial control cabinets, requiring uninhibited vertical airflow channels for natural thermal convection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the Frame Size A drive vertically on a standard 35 mm DIN rail or panel surface, maintaining a minimum clearance of 120 mm (4.7 in) above and below the chassis to enable unobstructed convective heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWire the single-phase 240 VAC input source to terminals L1 and L2 using copper conductors rated for 75 deg C, ensuring motor output leads (U, V, W) connect directly to 3-phase motor load terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-24 citation-end-24\"\u003eRoute analog signal wires (0-10V \/ 4-20 mA) in separate shielded cables, terminating cable shields to the drive functional ground point to minimize electro-magnetic noise coupling.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround the drive enclosure chassis by securing a heavy gauge copper conductor directly from the ground terminal to the main panel enclosure ground bus bar to ensure EMC compliance and surge protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":50573822918730,"sku":"22F-A2P5N103","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/22F-A2P5N103_1.png?v=1790671921","url":"https:\/\/www.topbrandsplc.com\/products\/22f-a2p5n103-allen-bradley-powerflex-4m-ac-drive","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}