{"product_id":"330101-00-50-05-02-00-bently-nevada-proximity-probes","title":"330101-00-50-05-02-00 | Bently Nevada | Proximity Probes","description":"\u003ch1\u003eBently Nevada 330101-00-50-05-02-00 3300 XL 8 mm Proximity Probe\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-00-50-05-02-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330101\u003c\/strong\u003e 3300 XL 8 mm Proximity Probe, operates as a dedicated hardware component for non-contact shaft displacement measurement within Bently Nevada 3300 XL transducer systems. The probe generates an eddy-current field and produces a signal proportional to the distance between the probe tip and conductive machine surfaces for vibration, position, and rotor dynamic monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e = 3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e = 0.0 in unthreaded length (fully threaded probe)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e50\u003c\/strong\u003e = 5.0 in overall case length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e = 0.5 m integral cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e = Miniature coaxial ClickLoc connector without armor configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e = Standard version without additional agency approval option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-00-50-05-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Size\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Construction\u003c\/td\u003e\n\u003ctd\u003eFully Threaded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e5.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Cable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m (1.6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eGold-Plated Miniature Coaxial ClickLoc Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003e75 Ohm Triaxial Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Insulation\u003c\/td\u003e\n\u003ctd\u003eFEP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePull Strength\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lbf)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Deviation\u003c\/td\u003e\n\u003ctd\u003e±0.065 mm Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Resistance\u003c\/td\u003e\n\u003ctd\u003e7.45 +\/- 0.50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Target Material\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eDefined by Model Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Probe Element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 330101-00-50-05-02-00 functions as the sensing element of a calibrated 3300 XL transducer system. When used together with a compatible 3300 XL extension cable and Proximitor sensor, the probe provides a linear measurement range of 2.0 mm for shaft displacement monitoring.\u003c\/p\u003e\n\u003cp\u003eCommissioning procedures typically include probe scaling verification and gap voltage validation. Proper gap adjustment ensures operation within the calibrated linear region and helps maintain the specified incremental scale factor of 7.87 V\/mm. In machinery protection systems, verification of probe positioning is commonly performed before vibration, thrust position, or rotor dynamic measurements are placed in service.\u003c\/p\u003e\n\u003cp\u003eThe triaxial cable construction and ClickLoc connector design assist in minimizing signal degradation, connector loosening, and cross-talk effects in high-vibration environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the probe be operated without a Proximitor sensor?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The probe is designed to operate as part of a complete 3300 XL transducer system consisting of a probe, extension cable, and compatible Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the calibrated linear measurement range?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified linear range is 2.0 mm (80 mils).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What material is used for factory calibration?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The probe is factory calibrated using an AISI 4140 steel target material.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify probe gap before final tightening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain separation from high-energy power cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid excessive bending of the triaxial cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm ClickLoc connector engagement before startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eValidate probe gap voltage during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":67709163176010,"sku":"330101-00-50-05-02-00","price":480.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/17_33cf1675-55fa-4388-b9ac-579216159a0f.jpg?v=1756793288","url":"https:\/\/www.topbrandsplc.com\/products\/330101-00-50-05-02-00-bently-nevada-proximity-probes","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}