{"product_id":"330171-00-15-10-11-05-bently-nevada-3300-5-mm-proximity-probes","title":"330171-00-15-10-11-05 | Bently Nevada | 3300 5 mm Proximity Probes","description":"\u003cp\u003e\u003cstrong\u003eBently Nevada 330171-00-15-10-11-05 3300 5 mm Proximity Probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eBently Nevada 330171-00-15-10-11-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330171\u003c\/strong\u003e Proximity Probe, operates as a dedicated hardware component for eddy-current displacement measurement within 3300 monitoring systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e330171\u003c\/strong\u003e: 3300 5 mm Proximity Probe, 1\/4-28 UNF thread, without armor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded length option (0.0 inches)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e-15\u003c\/strong\u003e: Overall case length option (1.5 inches)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e: Integral cable length (1.0 meter \/ 3.3 feet)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e-11\u003c\/strong\u003e: Miniature coaxial ClickLoc connector with protector and FluidLoc cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Agency approval option (multiple hazardous area certifications)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e330171-00-15-10-11-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eCase length 1.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePassive probe, powered via Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e1\/4-28 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e1.0 m integral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc with FluidLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMultiple hazardous area certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePrimary Use\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eFluid-film bearing machines, restricted installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRotor Dynamics and Cross-Talk Suppression\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 330171 probe is optimized for rotor dynamics monitoring in fluid-film bearing machines. Its eddy-current scaling ensures accurate displacement readings, while cross-talk suppression techniques reduce interference between probes installed in close proximity. The FluidLoc cable design further prevents leakage paths, maintaining signal integrity in harsh environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can the 330171 probe be hot-swapped during system operation? A: No, probes must be disconnected from the Proximitor before replacement to maintain calibration integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: What is the recommended grounding practice for the FluidLoc cable? A: Shielding should be grounded at the Proximitor end only to prevent ground loop currents.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Is the probe suitable for shafts larger than 51 mm? A: The 5 mm probe is intended for small shaft applications; larger shafts require 8 mm or 11 mm probe variants.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\u003cspan\u003eEngage 1\/4-28 UNF threads with at least 5 turns for secure seating.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoute integral cable away from high-voltage conductors to minimize induced noise.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGround shielding only at the Proximitor termination.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify gap voltage calibration (-10 VDC reference) during commissioning.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintain probe tip cleanliness; avoid abrasive contaminants on PPS material.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44015544827978,"sku":"330171-00-15-10-11-05","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/17_93ec7db0-1016-45f4-a9e2-99011a8e7d0b.jpg?v=1749103248","url":"https:\/\/www.topbrandsplc.com\/products\/330171-00-15-10-11-05-bently-nevada-3300-5-mm-proximity-probes","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}