{"product_id":"330190-040-00-05-bently-nevada-extension-cable","title":"330190-040-00-05 | Bently Nevada | Extension Cable","description":"\u003ch1\u003eBently Nevada 330190-040-00-05 Extension Cable\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330190-040-00-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330190\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for signal transmission and impedance-controlled interconnection within 3300 XL Extended Temperature Range (ETR) proximity transducer systems. The cable provides calibrated electrical continuity between the proximity probe and Proximitor sensor while maintaining displacement measurement accuracy under elevated temperature conditions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330190:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL Extended Temperature Range (ETR) Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e040:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.0 m cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard cable, without stainless steel armor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultiple approvals option including CSA, ATEX, and IECEx certifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330190-040-00-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL ETR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eETR Triaxial Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Option\u003c\/td\u003e\n\u003ctd\u003eStandard Non-Armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharacteristic Impedance\u003c\/td\u003e\n\u003ctd\u003e75 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCenter Conductor Resistance\u003c\/td\u003e\n\u003ctd\u003e7.59 Ohm\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCenter Conductor to Center Conductor Resistance\u003c\/td\u003e\n\u003ctd\u003e0.66 +\/- 0.10 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Conductor to Outer Conductor Resistance\u003c\/td\u003e\n\u003ctd\u003e0.20 +\/- 0.04 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Insulation Material\u003c\/td\u003e\n\u003ctd\u003ePerfluoroalkoxy (PFA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Material\u003c\/td\u003e\n\u003ctd\u003eGold-Plated Brass or Gold-Plated Beryllium Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Load\u003c\/td\u003e\n\u003ctd\u003e270 N (60 lbf)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +260 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.136 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.0 m Overall Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Cable Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 330190 extension cable is a calibrated element of the 3300 XL Extended Temperature Range transducer system. Electrical characteristics such as impedance, capacitance, and conductor resistance are controlled to maintain displacement measurement accuracy across the complete probe-extension cable-Proximitor assembly.\u003c\/p\u003e\n\u003cp\u003eProper system performance depends on matching the extension cable with approved 3300 XL ETR probes and Proximitor sensors configured for the correct system length. During commissioning, gap voltage validation is commonly performed to confirm the transducer system operates within its calibrated measurement region, typically centered near the standard -10 VDC target used in Bently Nevada eddy-current monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe PFA-insulated triaxial construction supports operation in locations where elevated temperatures exceed the limits of conventional proximity transducer cabling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 330190-040-00-05 be used with standard 3300 XL components?\u003c\/strong\u003e\u003cbr\u003eA: The extension cable is designed for 3300 XL Extended Temperature Range transducer systems and should be matched with compatible ETR system components to maintain calibration integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the cable require external power?\u003c\/strong\u003e\u003cbr\u003eA: No. The cable is a passive assembly and functions as part of the complete proximity transducer system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the cable suitable for high-temperature machinery installations?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The cable is rated for continuous operation from -52 deg C to +260 deg C and utilizes PFA insulation for elevated-temperature applications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify compatibility between the ETR probe, extension cable, and Proximitor sensor before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not shorten, splice, or modify the factory-calibrated cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain the minimum cable bend radius of 25.4 mm during routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute transducer cables separately from high-voltage and high-current conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtect connectors from contamination during installation and maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid exceeding the specified 270 N tensile load limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm shield continuity throughout the complete transducer system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify acceptable gap voltage values before placing machinery into service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":67639551787082,"sku":"330190-040-00-05","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/1_f92c35f3-ea1e-4680-9d6d-714ae459d9d0.jpg?v=1749023271","url":"https:\/\/www.topbrandsplc.com\/products\/330190-040-00-05-bently-nevada-extension-cable","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}