{"product_id":"5094-ob16s-allen-bradley-safety-digital-output-module","title":"5094-OB16S | Allen Bradley | Safety Digital Output Module","description":"\u003ch1\u003eAllen-Bradley 5094-OB16S FLEX 5000 Safety Digital Output Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for safety-related output control in EtherNet\/IP distributed I\/O systems, the \u003cstrong\u003eAllen-Bradley 5094-OB16S\u003c\/strong\u003e (\u003cstrong\u003e5094-OB16S\u003c\/strong\u003e Safety Digital Output Module) provides direct switching of field devices through safety-rated solid-state output channels. The module is designed for use within FLEX 5000 architectures and supports SIL 3, PLe, and Category 4 safety applications requiring monitored output execution and fault-tolerant operation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5094-OB16S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafety Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating\u003c\/td\u003e\n\u003ctd\u003e500 mA at 18-32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Actuator Power\u003c\/td\u003e\n\u003ctd\u003e8.2 A at 18-32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type\u003c\/td\u003e\n\u003ctd\u003eSA power-to-backplane, channels-to-backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eSIL 3, PLe, Category 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Voltage\u003c\/td\u003e\n\u003ctd\u003eVia FLEX 5000 platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Base Compatibility\u003c\/td\u003e\n\u003ctd\u003e5094-MB \/ 5094-MBXT series bases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Types\u003c\/td\u003e\n\u003ctd\u003eRTB3I, RTB3IS, RTB3IXT, RTB3ISXT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Category\u003c\/td\u003e\n\u003ctd\u003eCategory 2 signal ports, Category 2 power ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e0.34-2.5 mm2 (22-14 AWG) copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Torque\u003c\/td\u003e\n\u003ctd\u003e0.4 N m (3.5 lb in) screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Classification\u003c\/td\u003e\n\u003ctd\u003eISA S71.04 G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Classification XT Version\u003c\/td\u003e\n\u003ctd\u003eISA S71.04 G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Surrounding Air Temp\u003c\/td\u003e\n\u003ctd\u003e70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Code\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eI\/O Density Scaling for FLEX 5000 Safety Systems\u003c\/h3\u003e\n\u003cp\u003eThe 5094-OB16S integrates into FLEX 5000 distributed I\/O assemblies, allowing safety output functions to be expanded through a modular architecture. The module interfaces with compatible FLEX 5000 mounting bases and participates in the platform backplane communication structure used by EtherNet\/IP adapters and Logix controllers.\u003c\/p\u003e\n\u003cp\u003eThe distributed design supports scalable deployment of safety outputs while maintaining common installation practices across standard and safety I\/O assemblies. Corrosion-resistant XT versions are available for installations requiring enhanced environmental protection.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What safety certification level does the module support?\u003c\/strong\u003e\u003cbr\u003eA: The module is specified for SIL 3, Performance Level e (PLe), and Category 4 safety applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum output capacity per channel?\u003c\/strong\u003e\u003cbr\u003eA: The output rating is 500 mA with an operating voltage range of 18-32 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is field-side isolation provided?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module provides 250 V continuous isolation between sensor actuator power and the backplane, as well as between output channels and the backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module on a compatible 5094-MB or 5094-MBXT mounting base before applying field power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that sensor actuator power remains within the specified 18-32 VDC operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse only copper conductors meeting the specified wire gauge and temperature requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply the specified terminal tightening torque when utilizing screw-type terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute output power conductors separately from communication cables and sensitive analog circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module within a suitable industrial enclosure because the product utilizes an open-style housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify output channel operation and safety function response during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect terminal connections periodically to ensure continued mechanical integrity and electrical continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67717768085578,"sku":"5094-OB16S","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/5094-IB16S_1.png?v=1792209416","url":"https:\/\/www.topbrandsplc.com\/products\/5094-ob16s-allen-bradley-safety-digital-output-module","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}