{"product_id":"aab841-s03-m4a00-yokogawa-analog-i-o-module","title":"AAB841-S03\/M4A00 | Yokogawa | Analog I\/O Module","description":"\u003ch2\u003eYokogawa AAB841-S03\/M4A00 Analog I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AAB841-S03\/M4A00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAAB841\u003c\/strong\u003e analog I\/O module, operates as a rack-mounted PCB assembly for voltage input and current output signal processing within Yokogawa control systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAAB841\u003c\/strong\u003e: Analog I\/O Module (1–5 V input, 4–20 mA output, 8-channel input\/8-channel output, non-isolated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-S03\u003c\/strong\u003e: Standard type with ISA G3 option and extended temperature range (-20 to +70 deg C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/M4A00\u003c\/strong\u003e: Equipped with MAC2 compatible adapter (ATM4A-00)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eAAB841-S03\/M4A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eYokogawa control platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e0.3 kg (shipping weight 1.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eStandard rack plug-in size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e-20 to +70 deg C (ISA G3 option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eSupplied via backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eAnalog I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e1–5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOutput Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e8 inputs \/ 8 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAdapter Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMAC2 compatible adapter ATM4A-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFOUNDATION Fieldbus \/ Profibus PA Connectivity\u003c\/h3\u003e\n\u003cp\u003eAlthough the AAB841-S03\/M4A00 is a non-isolated analog I\/O module, integration with Yokogawa systems often involves FOUNDATION Fieldbus or Profibus PA connectivity through external adapters. This ensures deterministic communication across distributed networks, while the MAC2 adapter option provides compatibility with legacy MAC2 interfaces. Channel grouping allows efficient scaling of analog signals in multi-loop environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AAB841-S03\/M4A00 operate in extended temperature environments? A: Yes, the -S03 suffix includes ISA G3 compliance and supports -20 to +70 deg C operation.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide isolation between channels? A: No, the AAB841 is a non-isolated analog I\/O module; isolation must be managed externally.\u003c\/p\u003e\n\u003cp\u003eQ: What adapter is included with the \/M4A00 option? A: The \/M4A00 option includes the MAC2 compatible adapter ATM4A-00.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall module into designated rack slots; ensure full connector engagement.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between analog wiring and high-voltage conductors to reduce interference.\u003c\/li\u003e\n\u003cli\u003eVerify MAC2 adapter orientation and secure harness connections.\u003c\/li\u003e\n\u003cli\u003eObserve environmental limits (-20 to +70 deg C) for reliable operation.\u003c\/li\u003e\n\u003cli\u003eConfirm grounding continuity for shielding layers to minimize EMI.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44139152703562,"sku":"AAB841-S03\/M4A00","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/CP461-10S1_3.png?v=1744341693","url":"https:\/\/www.topbrandsplc.com\/products\/aab841-s03-m4a00-yokogawa-analog-i-o-module","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}