{"product_id":"abb-3bhb003041r0101-uf-c719-ae01-i-o-control-board-ioec-in-stock","title":"ABB 3BHB003041R0101 UF C719 AE01 I\/O CONTROL BOARD IOEC in stock","description":"\u003ch2\u003eABB UF C719 AE01 IOEC I\/O Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB UF C719 AE01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3BHB003041R0101\u003c\/strong\u003e control board, operates as a dedicated IOEC interface module for mixed‑signal acquisition and command execution across ACS‑series medium‑voltage drives, UNITROL excitation systems, and Advant Master process networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eUF C719 AE01 \/ 3BHB003041R0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eSlovakia \/ Switzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.71–1.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e45.3 cm × 12.8 cm × 4.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temp\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule Type\u003c\/th\u003e\n\u003ctd\u003eIOEC I\/O interface module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eI\/O Capacity\u003c\/th\u003e\n\u003ctd\u003e32‑channel, 16‑bit configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal Types\u003c\/th\u003e\n\u003ctd\u003eAnalog input\/output, digital input\/output, relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eSupports up to 16 external I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eMasterbus 300, Ethernet, RS‑485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHot‑Swap\u003c\/th\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eIEC 61131‑2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS Code\u003c\/th\u003e\n\u003ctd\u003e85049099 \/ 85389070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eWithin ABB ACS‑series drive architectures, the UF C719 AE01 participates in deterministic backplane communication governed by the IOEC control layer. Its multi‑protocol serial interfaces allow mixed‑network operation without introducing timing drift across high‑density I\/O expansions. Firmware flash compatibility across ACS 1000, ACS 2000, and UNITROL 1000 platforms ensures stable synchronization during module replacement or hot‑swap events. The board’s layout supports I\/O density scaling while maintaining isolation between analog, digital, and relay circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the UF C719 AE01 be replaced while the drive remains energized? A: Yes. The module is designed for hot‑swap operation within supported ACS and UNITROL systems.\u003c\/p\u003e\n\u003cp\u003eQ: Does adding external I\/O modules affect communication timing? A: No. The IOEC architecture maintains deterministic scheduling across up to 16 connected modules.\u003c\/p\u003e\n\u003cp\u003eQ: Are protocol selections fixed at installation? A: No. Supported serial interfaces (Masterbus 300, Ethernet, RS‑485) are configured at the system level.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain correct seating in the drive or excitation chassis to ensure stable backplane contact.\u003c\/li\u003e\n\u003cli\u003eRoute analog, digital, and relay wiring separately to reduce cross‑coupling.\u003c\/li\u003e\n\u003cli\u003eBond shields at a single grounding point to avoid circulating currents.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bends in ribbon or harness cables to preserve conductor integrity.\u003c\/li\u003e\n\u003cli\u003eVerify environmental conditions when installing boards with protective housings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41240460951626,"sku":"UFC719AE01 3BHB003041R0101","price":540.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/UFC719AE013BHB003041R0101_4.jpg?v=1741077998","url":"https:\/\/www.topbrandsplc.com\/products\/abb-3bhb003041r0101-uf-c719-ae01-i-o-control-board-ioec-in-stock","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}