{"product_id":"allen-bradley-1766-mm1-micrologix-1400-memory-module","title":"Allen Bradley 1766-MM1 MicroLogix 1400 Memory Module","description":"\u003cp data-path-to-node=\"0\"\u003e\u003cstrong\u003eAllen Bradley 1766-MM1 MicroLogix 1400 Memory Module\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eAllen Bradley 1766-MM1\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"1\" data-index-in-node=\"50\"\u003e1766-MM1\u003c\/b\u003e Memory Module, operates as a dedicated hardware component for firmware backup and application program storage within MicroLogix 1400 PLC platforms.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable data-path-to-node=\"3\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,1,1,0\"\u003e1766-MM1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,2,1,0\"\u003eAllen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,3,0,0\"\u003eSeries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,3,1,0\"\u003eMicroLogix 1400 Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,4,0,0\"\u003eProduct Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,4,1,0\"\u003eNon-volatile Memory Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,5,0,0\"\u003eMemory Capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,5,1,0\"\u003e128 KB User Application \u0026amp; Data Memory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,6,0,0\"\u003eMemory Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,6,1,0\"\u003eEEPROM Flash Memory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,7,0,0\"\u003eFirmware Flash Compatibility\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,7,1,0\"\u003eMicroLogix 1400 Series A and Series B Controllers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,8,0,0\"\u003eRetention Period\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,8,1,0\"\u003e20 Years minimum without controller power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,9,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,9,1,0\"\u003e-20 to 60 deg C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,10,0,0\"\u003eNet Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,10,1,0\"\u003e0.05 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,11,0,0\"\u003eShipping Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-path-to-node=\"3,11,1,0\"\u003e0.5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"4\"\u003e\u003cstrong\u003eBackplane Communication and Execution Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe Allen Bradley 1766-MM1 module provides non-volatile data logging and user program backup for MicroLogix 1400 processors. Designed to preserve system ladder logic during complete power loss or primary battery failure, the module supports automatic flash loading upon power-up routines. The memory architecture enforces strict backplane bus communication velocity Licences and program verification cycles, ensuring deterministic logic execution and seamless firmware flash compatibility across network nodes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eQ: Can the 1766-MM1 memory module be installed or removed while the MicroLogix 1400 controller is powered?\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eA: No, power to the controller must be completely de-energized before inserting or removing the memory module to avoid memory corruption or physical pin damage.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eQ: How is automatic program loading configured using the 1766-MM1 module?\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eA: Auto-loading behavior (such as \"Load on Error\" or \"Load Always\") is configured in the controller properties within RSLogix 500 programming software prior to downloading the project to the memory module.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003eRemove 24 VDC or AC power from the MicroLogix 1400 controller before opening the memory module protective cover.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003eTouch a grounded metal surface to discharge static electricity prior to handling the electrostatic-sensitive 1766-MM1 card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003eAlign the memory module keying tabs with the dedicated memory socket on the front face of the controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003ePress the module firmly into the socket until the retaining clips click securely into place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003eRestore controller power and verify that the controller diagnostic LCD or software status indicates successful memory module detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43836122202186,"sku":"1766-MM1","price":530.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/1766-L32BWAA_2.jpg?v=1741073972","url":"https:\/\/www.topbrandsplc.com\/products\/allen-bradley-1766-mm1-micrologix-1400-memory-module","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}