{"product_id":"allen-bradley-1784-u2cn-usb-to-controlnet-cable","title":"Allen Bradley 1784-U2CN USB-to-ControlNet Cable","description":"\u003cdiv class=\"flex max-w-full flex-col flex-grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message flex w-full flex-col items-end gap-2 whitespace-normal break-words text-start [.text-message+\u0026amp;]:mt-5\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"\u003e\n\u003cdiv class=\"markdown prose w-full break-words dark:prose-invert light\"\u003e\n\u003ch2\u003eAllen-Bradley 1784-U2CN USB-to-ControlNet Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1784-U2CN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1784-U2CN\u003c\/strong\u003e USB-to-ControlNet cable, operates as a dedicated interface for connecting USB-enabled programming devices to ControlNet networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e1784-U2CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eStandard cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temp\u003c\/th\u003e\n\u003ctd\u003e-10 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003eMax 0.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e5.00 VDC nominal, 5.25 VDC max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply Current\u003c\/th\u003e\n\u003ctd\u003e75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation Voltage\u003c\/th\u003e\n\u003ctd\u003e30 V continuous, type tested at 500 V AC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControlNet Current\u003c\/th\u003e\n\u003ctd\u003e70 mA @ 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCore Function\u003c\/th\u003e\n\u003ctd\u003eUSB-to-ControlNet communication cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 1784-U2CN cable is designed to provide deterministic communication between USB programming devices and ControlNet nodes. Isolation voltage testing ensures safe operation across USB and ControlNet domains. Compliance with CISPR 11 Class A emissions and IEC 61000 immunity standards allows integration into industrial environments without interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 1784-U2CN be used in environments with high EMI? A: Yes, the cable meets IEC 61000-4-2 and IEC 61000-4-3 immunity standards, supporting operation under strong EMI\/RFI conditions.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum power dissipation? A: The cable dissipates up to 0.5 W under full load.\u003c\/p\u003e\n\u003cp\u003eQ: Does the cable provide galvanic isolation? A: Yes, it provides 30 V continuous isolation, type tested at 500 V AC for 60 s between ControlNet and USB.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure USB and ControlNet connectors are fully seated before energizing.\u003c\/li\u003e\n\u003cli\u003eMaintain ambient temperature between 0 and 55 deg C during operation.\u003c\/li\u003e\n\u003cli\u003eRoute cabling away from high-voltage conductors to minimize induced noise.\u003c\/li\u003e\n\u003cli\u003eVerify grounding practices to maintain compliance with IEC 61000 immunity standards.\u003c\/li\u003e\n\u003cli\u003eInspect cable jacket and connectors for mechanical integrity before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44110500921418,"sku":"1784-U2CN","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/1769-CRL3_1.png?v=1741073710","url":"https:\/\/www.topbrandsplc.com\/products\/allen-bradley-1784-u2cn-usb-to-controlnet-cable","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}