{"product_id":"bently-nevada-24701-33-05-00-029-04-02-proximity-probe-housing-assemblies","title":"Bently Nevada 24701-33-05-00-029-04-02 Proximity Probe Housing Assemblies","description":"\u003ch2\u003eBently Nevada 24701-33-05-00-029-04-02 Proximity Probe Housing Assemblies\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 24701-33-05-00-029-04-02\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e24701\u003c\/strong\u003e housing assembly, serves as the primary stainless steel enclosure for 3300 XL proximity probes, enabling mechanical protection and external adjustment within turbine supervisory instrumentation systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24701\u003c\/strong\u003e: Stainless steel proximity probe housing series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e33\u003c\/strong\u003e: 3300 XL 8 mm probe with connector protector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: 0.5-meter probe cable length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: No standoff adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e029\u003c\/strong\u003e: 2.9-inch probe penetration depth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e04\u003c\/strong\u003e: Specific conduit\/fittings configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: 3\/4-14 NPT mounting thread option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e24701-33-05-00-029-04-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eProbe penetration depth 2.9 in, cable length 0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003eMatches probe specification (-52 deg C to +177 deg C typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003ePassive housing, no electrical load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Material\u003c\/th\u003e\n\u003ctd\u003eStainless steel (AISI grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Thread\u003c\/th\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility\u003c\/th\u003e\n\u003ctd\u003eDesigned for 3300 XL 8 mm proximity probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eMoisture, dust, and mechanical shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe housing assembly design minimizes electromagnetic interference between adjacent probe channels. By maintaining coaxial shielding continuity and mechanical separation, cross-talk suppression ensures accurate eddy-current displacement signals during rotor dynamics monitoring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the housing be installed without removing machine covers? A: Yes. It allows external probe adjustment and replacement without opening the machine casing.\u003c\/p\u003e\n\u003cp\u003eQ: Does the housing affect probe calibration? A: No. The housing provides mechanical protection only; calibration remains defined by the probe and Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eQ: What thread engagement is required for secure installation? A: A minimum of 5 turns on the 3\/4-14 NPT thread is recommended for mechanical stability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign housing penetration depth with specified probe tip clearance before tightening.\u003c\/li\u003e\n\u003cli\u003eEnsure NPT threads are engaged with proper torque to prevent vibration loosening.\u003c\/li\u003e\n\u003cli\u003eRoute conduit and fittings per industrial standards to maintain environmental sealing.\u003c\/li\u003e\n\u003cli\u003eGround shielding at the Proximitor end only to avoid ground loops.\u003c\/li\u003e\n\u003cli\u003eInspect connector protector seals to confirm moisture resistance before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44044941393994,"sku":"24701-33-05-00-029-04-02","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/21000_2.png?v=1751600385","url":"https:\/\/www.topbrandsplc.com\/products\/bently-nevada-24701-33-05-00-029-04-02-proximity-probe-housing-assemblies","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}