{"product_id":"bently-nevada-330101-02-12-10-11-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-02-12-10-11-00 3300 XL 8 mm Proximity Probe","description":"\u003ch2\u003eBently Nevada 330101-02-12-10-11-00 3300 XL 8 mm Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eConfigured for rotor dynamic displacement measurement in turbine supervisory instrumentation (TSI) systems, the \u003cstrong\u003eBently Nevada 330101-02-12-10-11-00\u003c\/strong\u003e (\u003cstrong\u003e330101\u003c\/strong\u003e proximity probe) provides direct eddy-current signal acquisition.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330101: 3300 XL 8 mm Proximity Probe model\u003c\/li\u003e\n\u003cli\u003e02: Unthreaded length option\u003c\/li\u003e\n\u003cli\u003e12: Overall case length option\u003c\/li\u003e\n\u003cli\u003e10: Total probe cable length (1.0 meter)\u003c\/li\u003e\n\u003cli\u003e11: Connector and cable-type option (miniature coaxial ClickLoc connector with protector)\u003c\/li\u003e\n\u003cli\u003e00: Agency approval option (Standard \/ Non-hazardous)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e330101-02-12-10-11-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eCase length 12 mm, cable length 1.0 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e-51 deg C to +177 deg C (typical for 3300 XL probes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003ePassive probe, powered via Proximitor sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTip Size\u003c\/th\u003e\n\u003ctd\u003e8 mm eddy-current proximity tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLinear Range\u003c\/th\u003e\n\u003ctd\u003e2 mm (80 mils) linear operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eScaling Factor\u003c\/th\u003e\n\u003ctd\u003e7.87 mV\/μm (200 mV\/mil) nominal output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterchangeability\u003c\/th\u003e\n\u003ctd\u003eFully interchangeable with 3300 XL Proximitor sensors and extension cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe probe output is referenced to a nominal -10 VDC gap voltage target, ensuring consistent displacement scaling across interchangeable probes. This validation supports accurate rotor dynamics monitoring and suppresses cross-talk between adjacent channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the probe support hot-swap installation? A: No. The probe requires full system power-down before mechanical removal or replacement to avoid signal integrity issues.\u003c\/p\u003e\n\u003cp\u003eQ: What is the typical backplane current load when connected via Proximitor? A: The probe itself is passive; current load is defined by the Proximitor sensor, typically within milliamps range.\u003c\/p\u003e\n\u003cp\u003eQ: Can the probe be used with non-3300 XL extension cables? A: No. Only 3300 XL extension cables are supported to maintain scaling accuracy and interchangeability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure probe tip is aligned perpendicular to the shaft surface for accurate displacement measurement.\u003c\/li\u003e\n\u003cli\u003eMaintain shield continuity by grounding the coaxial cable shield at the Proximitor end only.\u003c\/li\u003e\n\u003cli\u003eAvoid routing probe cables parallel to high-voltage conductors to minimize induced noise.\u003c\/li\u003e\n\u003cli\u003eEngage NPT threads with a minimum of 5 turns to secure mechanical stability.\u003c\/li\u003e\n\u003cli\u003eVerify gap voltage at installation (-10 VDC nominal) before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44044724535370,"sku":"330101-02-12-10-11-00","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/3_8ef043ba-878d-4c16-9276-22db70f92af3.jpg?v=1766716242","url":"https:\/\/www.topbrandsplc.com\/products\/bently-nevada-330101-02-12-10-11-00-3300-xl-8-mm-proximity-probe","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}