{"product_id":"bently-nevada-330101-30-49-10-12-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-30-49-10-12-05 3300 XL 8 mm Proximity Probe","description":"\u003ch2\u003eBently Nevada 330101-30-49-10-12-05 3300 XL 8 mm Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eConfigured for static position and dynamic vibration monitoring in turbine supervisory instrumentation (TSI) systems, the \u003cstrong\u003eBently Nevada 330101-30-49-10-12-05\u003c\/strong\u003e (\u003cstrong\u003e330101\u003c\/strong\u003e proximity probe) provides direct eddy-current signal acquisition.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe (base model, unthreaded length\/case configuration options)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30\u003c\/strong\u003e: Unthreaded length option (3.0 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e49\u003c\/strong\u003e: Overall cable length option (4.9 meters)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e: 3\/8-24 UNF thread size without armor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12\u003c\/strong\u003e: Multiple agency approval option (ATEX \/ IECEx \/ HazLoc certifications)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: Functional connector option (fluidloc coaxial connector with protector, or specific built-in connector grade)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e330101-30-49-10-12-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eProbe tip 8 mm, unthreaded length 3.0 inches, cable length 4.9 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e-52 deg C to +177 deg C (typical for XL probes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003ePassive probe, powered via Proximitor sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCore Features\u003c\/th\u003e\n\u003ctd\u003eTipLoc molding, CableLoc design, full interchangeability with 3300 XL extension cables and Proximitor sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling\u003c\/h3\u003e\n\u003cp\u003eThe probe maintains linear eddy-current response scaling across rotor dynamics monitoring ranges. Gap voltage validation is achieved with -10 VDC reference targets, ensuring accurate displacement measurements. Cross-talk suppression is embedded in the coaxial connector design, minimizing interference between adjacent channels in dense rack configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the probe support hot-swap installation? A: The probe itself is passive and can be physically replaced without power cycling, but associated Proximitor modules must be isolated before reconnection.\u003c\/p\u003e\n\u003cp\u003eQ: What is the expected backplane current load from this probe? A: The probe does not directly load the backplane; current draw is defined by the Proximitor sensor interface.\u003c\/p\u003e\n\u003cp\u003eQ: Is firmware compatibility relevant for this probe? A: No. The probe is a passive hardware device; firmware updates apply only to monitoring modules, not to the probe itself.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure probe tip engagement with thread specifications (3\/8-24 UNF) to achieve stable mechanical seating.\u003c\/li\u003e\n\u003cli\u003eMaintain shielded cable routing with proper grounding at the Proximitor end to suppress noise.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bends in the 4.9 m cable to preserve impedance integrity.\u003c\/li\u003e\n\u003cli\u003eVerify hazardous area approvals (ATEX \/ IECEx) before installation in classified zones.\u003c\/li\u003e\n\u003cli\u003eConfirm gap voltage calibration (-10 VDC reference) during commissioning to validate displacement accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44049155784778,"sku":"330101-30-49-10-12-05","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/3_8ef043ba-878d-4c16-9276-22db70f92af3.jpg?v=1766716242","url":"https:\/\/www.topbrandsplc.com\/products\/bently-nevada-330101-30-49-10-12-05-3300-xl-8-mm-proximity-probe","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}