{"product_id":"fc-dcom-232-485-cc-v2-1-honeywell-communication-interface-fta","title":"FC-DCOM-232\/485 CC V2.1 | Honeywell | Communication Interface FTA","description":"\u003ch1\u003eHoneywell FC-DCOM-232\/485 CC V2.1 Communication Interface FTA\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-DCOM-232\/485 CC V2.1\u003c\/strong\u003e is a Communication Interface Field Termination Assembly (FTA) designed to provide RS232 and RS485\/422 communication interfaces for Honeywell control systems. The module supports multiple serial communication standards, wide baud rate ranges, and DIN rail installation, enabling reliable connectivity between control processors and external serial devices.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-DCOM-232\/485 CC V2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Interface FTA for RS232\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003eMax. 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eSupplied by Control Processor(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Output Standard\u003c\/td\u003e\n\u003ctd\u003eEIA\/TIA-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Baud Rate\u003c\/td\u003e\n\u003ctd\u003e0-250 kBaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485\/422 Output Standard\u003c\/td\u003e\n\u003ctd\u003eEIA\/TIA-485-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485\/422 Baud Rate\u003c\/td\u003e\n\u003ctd\u003e0-2 MBaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoding Support\u003c\/td\u003e\n\u003ctd\u003eTransparent, FM0, FM1, Manchester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDIN Rail Type\u003c\/td\u003e\n\u003ctd\u003eTS32, TS35 x 7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRail Length Required\u003c\/td\u003e\n\u003ctd\u003e11.7 cm (4.6 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e11 cm x 7 cm x 6.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommunication Interface Function\u003c\/h3\u003e\n\u003cp\u003eThe FC-DCOM-232\/485 CC V2.1 acts as a field termination and interface module between Honeywell control processors and serial communication devices. It supports both RS232 and RS485\/422 electrical standards, allowing integration with a wide range of industrial equipment and communication networks.\u003c\/p\u003e\n\u003cp\u003eThe module receives operating power directly from the connected control processor, eliminating the need for a separate field power supply under normal installation conditions.\u003c\/p\u003e\n\u003ch3\u003eRS232 and RS485\/422 Support\u003c\/h3\u003e\n\u003cp\u003eThe RS232 interface complies with EIA\/TIA-232 signal levels and supports communication rates up to 250 kBaud. This interface is suitable for point-to-point serial communication with compatible industrial devices.\u003c\/p\u003e\n\u003cp\u003eFor higher-speed and longer-distance communication requirements, the module provides an RS485\/422 interface compliant with EIA\/TIA-485-A standards. Supported baud rates extend to 2 MBaud, enabling efficient exchange of process and diagnostic data.\u003c\/p\u003e\n\u003ch3\u003eData Encoding Options\u003c\/h3\u003e\n\u003cp\u003eThe RS485\/422 interface supports multiple transmission formats, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTransparent communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFM0 encoding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFM1 encoding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManchester encoding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese options allow the interface to accommodate different communication requirements and system architectures where specialized encoding methods are required.\u003c\/p\u003e\n\u003ch3\u003eInstallation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module is designed for mounting on standard TS32 or TS35 x 7.5 DIN rails. A minimum rail length of 11.7 cm (4.6 in) is required for installation.\u003c\/p\u003e\n\u003cp\u003eIts compact enclosure simplifies integration into control cabinets where panel space is limited while maintaining accessibility for field wiring and maintenance.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication standards are supported by the FC-DCOM-232\/485 CC V2.1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module supports both RS232 and RS485\/422 communication interfaces in accordance with EIA\/TIA-232 and EIA\/TIA-485-A standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum supported baud rate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The RS232 interface supports up to 250 kBaud, while the RS485\/422 interface supports communication rates up to 2 MBaud.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified input power is 5 VDC, with a maximum current requirement of 500 mA, supplied directly by the associated Honeywell control processor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which DIN rail types are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for installation on TS32 or TS35 x 7.5 DIN rails and requires approximately 11.7 cm of rail space.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":41332101251146,"sku":"FC-DCOM-232\/485 CC V2.1","price":390.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/FC-DCOM-232485_3.jpg?v=1741077819","url":"https:\/\/www.topbrandsplc.com\/products\/fc-dcom-232-485-cc-v2-1-honeywell-communication-interface-fta","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}