{"product_id":"ge-ds200fcsag2a-current-sensing-feedback-board","title":"GE DS200FCSAG2A Current Sensing Feedback Board","description":"\u003ch1\u003eGE DS200FCSAG2A Current Sensing Feedback Board\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200FCSAG2A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200FCSAG2A\u003c\/strong\u003e Current Sensing Feedback Board, operates as a dedicated hardware component for current sensing, feedback acquisition, and power conversion monitoring within the GE LS2100 static starter control system. The board interfaces with current sensing devices and control power circuits to provide feedback data required for drive system regulation and starter cabinet operation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200FCSAG2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCurrent Sensing Feedback Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eFCSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eLS2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric Company USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Function\u003c\/td\u003e\n\u003ctd\u003eCurrent Sensor Interface and Feedback Processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eStatic Starter Power Conversion Cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated System\u003c\/td\u003e\n\u003ctd\u003eLS2100 Static Starter System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Power Supply\u003c\/td\u003e\n\u003ctd\u003eControl Power Supply (CPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e3-Pin LEMPS Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e12-Pin CSPL Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPS Supply Outputs\u003c\/td\u003e\n\u003ctd\u003e24 V, 15 V, 12 V, and 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction Guide\u003c\/td\u003e\n\u003ctd\u003eGEH-6678\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParts Manual\u003c\/td\u003e\n\u003ctd\u003eGEI-100222\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePower Conversion Feedback and Current Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe DS200FCSAG2A performs current feedback acquisition within the LS2100 static starter architecture. Installed inside the power conversion cabinet, the board interfaces with current sensing hardware and transfers feedback information required by the starter control system.\u003c\/p\u003e\n\u003cp\u003eThe board operates with the associated Control Power Supply (CPS), which provides regulated output voltages including 24 V, 15 V, 12 V, and 5 V to supporting circuitry. Current feedback information collected by the FCSA board assists in monitoring and regulating power conversion functions associated with gas turbine generator prime mover applications.\u003c\/p\u003e\n\u003cp\u003eCommunication with sensing circuitry is accomplished through dedicated interfaces including the LEMPS and CSPL connectors. The LEMPS connector is also utilized during voltage verification procedures to isolate auxiliary circuit influences when performing diagnostic checks.\u003c\/p\u003e\n\u003ch3\u003eFirmware Compatibility and System Integration\u003c\/h3\u003e\n\u003cp\u003eWithin the LS2100 platform, the DS200FCSAG2A functions alongside multiple drive control assemblies installed in the static starter cabinet. The board is identified in GE documentation under the FCSA designation and serves as a dedicated sensing interface rather than a standalone control processor.\u003c\/p\u003e\n\u003cp\u003eCorrect installation requires compatibility with the designated LS2100 hardware environment and associated current sensing components. Verification of CPS-generated supply voltages at the specified test points is commonly performed during maintenance and commissioning procedures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary purpose of the DS200FCSAG2A board?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The board functions as a Current Sensing Feedback Board that acquires and processes current feedback signals within the LS2100 static starter system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What connectors are installed on the board?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The board includes a 3-pin LEMPS connector and a 12-pin CSPL connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How can supply voltage verification be performed?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Voltage verification is performed at the referenced CPS-related test points. The LEMPS connector may be disconnected during troubleshooting procedures to eliminate auxiliary circuit influence during measurement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIsolate cabinet power before servicing the board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify connector orientation before insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect LEMPS and CSPL connectors for secure engagement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm CPS output voltages before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain separation between sensing and power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":67696100212810,"sku":"DS200FCSAG2A","price":290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/DS200FCSAG2A_3.png?v=1792046230","url":"https:\/\/www.topbrandsplc.com\/products\/ge-ds200fcsag2a-current-sensing-feedback-board","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}