{"product_id":"ge-is220phrah1a-mark-vie-hart-analog-i-o-module","title":"GE IS220PHRAH1A Mark VIe HART Analog I\/O Module","description":"\u003ch1\u003eGE IS220PHRAH1A Mark VIe HART Analog I\/O Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for high-density analog acquisition and turbine signal processing in Mark VIe platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IS220PHRAH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eIS220PHRAH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog I\/O Pack) provides direct physical\/electrical execution. The distributed I\/O module conditions up to 10 analog input signals and drives 2 analog outputs while multiplexing bidirectional HART communication across dual-redundant Ethernet IONet networks\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS220PHRAH1A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.26 cm high x 4.19 cm wide\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 deg C to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC input via 3-pin power connector (inherent soft-start capability)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 channels (8 configurable for 4-20 mA \/ +-5 VDC; 2 configurable for 4-20 mA \/ +-1 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eADC Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit analog-to-digital converter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNormal Scan Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 ms (200 Hz scan rate)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBetter than 0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 channels (4-20 mA, 14-bit DAC, 18 V compliance)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual RJ-45 Ethernet connectors (ENET1\/ENET2 IONet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IS220PHRAH1A packs high-density analog acquisition and HART digital communication into a compact module footprint. Dual RJ-45 Ethernet interfaces establish deterministic network communication with host Mark VIe controllers over primary and secondary IONet links. Analog input signals pass through second-order low-pass filters (12.5 Hz and 48.3 Hz poles) before digitized by a 16-bit ADC, maintaining a normal 5 ms scan execution speed. Integrated firmware flash compatibility enables dual HART modems (Modem A covering inputs 1-5 and output 1; Modem B covering inputs 6-10 and output 2) to route Asset Management System (AMS) digital records while ensuring continuous channel-to-channel isolation and output loop tracking.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the HART multiplexing architecture affect parameter update rates across field devices?\u003c\/p\u003e\n\u003cp\u003eA: The 12 HART channels are split between two internal modems. If only one channel on a modem is active, data updates roughly once per second. If all six channels assigned to a modem are active, update latency scales to approximately eight seconds per channel.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IS220PHRAH1A module be plugged in while system power is active?\u003c\/p\u003e\n\u003cp\u003eA: Yes, power can be applied by plugging in the 3-pin side power connector without de-energizing the main power cable because the module includes internal soft-start circuitry that controls initial current inrush.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the terminal board securely and plug the PHRA pack directly into the DC-62 pin connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the mounting bracket location so that no right-angle mechanical force is applied to the DC-62 pin connector interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the I\/O pack mechanically using the threaded studs adjacent to the dual Ethernet ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect ENET1 to the Ethernet network associated with the R controller in redundant Mark VIe architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that terminal board 250-ohm burden resistors are engaged when configuring channels 1 through 8 for 4-20 mA current loop mode to ensure accurate 5 VDC conversion at 20 mA full scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45889810432074,"sku":"IS220PHRAH1A","price":290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/IS220PDOAH1B_1.jpg?v=1741074083","url":"https:\/\/www.topbrandsplc.com\/products\/ge-is220phrah1a-mark-vie-hart-analog-i-o-module","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}