{"product_id":"honeywell-c300-system-cc-paox01-51405039-275-analog-output-module","title":"Honeywell | C300 System | CC-PAOX01 51405039-275 | Analog Output Module","description":"\u003ch2\u003eHoneywell CC-PAOX01 51405039-275 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog drive execution in Experion PKS C300 I\/O assemblies, the \u003cstrong\u003eHoneywell CC-PAOX01 51405039-275\u003c\/strong\u003e (\u003cstrong\u003eCC‑PAOX01\u003c\/strong\u003e analog output module) provides 16 non‑isolated 4–20 mA channels with calibrated resolution and controlled switchover behavior. It maintains deterministic output settling for closed‑loop control paths.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eCC-PAOX01 51405039-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.9kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule Type\u003c\/th\u003e\n\u003ctd\u003e16‑channel analog output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Type\u003c\/th\u003e\n\u003ctd\u003e4–20 mA (non‑HART), 0 mA, 2.9–21.1 mA range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e16‑bit (±0.05% F.S.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±0.35% F.S. calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Drift\u003c\/th\u003e\n\u003ctd\u003e0.005% per deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad Capacity\u003c\/th\u003e\n\u003ctd\u003e800 Ω max (24 V supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRipple\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100 mV peak‑to‑peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSettling Time\u003c\/th\u003e\n\u003ctd\u003e80 ms to 1% of final value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy Gap\u003c\/th\u003e\n\u003ctd\u003eMax 10 ms during switchover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e5% to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePlatform\u003c\/th\u003e\n\u003ctd\u003eExperion PKS C300 Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIOTA Compatibility\u003c\/th\u003e\n\u003ctd\u003eCC‑TAOX01\/GAOX21 (non‑redundant), CC‑TAOX11\/GAOX11 (redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation Behavior\u003c\/h3\u003e\n\u003cp\u003eAlthough the CC‑PAOX01 outputs non‑HART analog signals, its internal routing architecture aligns with Honeywell’s mixed‑protocol environments where 4–20 mA HART loops may coexist with digital Fieldbus\/PA segments. Channel‑to‑channel isolation in adjacent I\/O assemblies prevents drift when high‑density analog outputs operate near RS‑485 or MODBUS wiring. Cold junction compensation (CJC) circuits in nearby modules remain unaffected due to the module’s controlled thermal profile and stable reference grounding.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CC‑PAOX01 be hot‑swapped in a C300 chassis? A: Hot‑swap behavior depends on the IOTA base. The module itself does not impose switching restrictions but must follow cabinet isolation procedures.\u003c\/p\u003e\n\u003cp\u003eQ: Does redundancy switchover affect analog output stability? A: The module maintains a maximum 10 ms output gap during switchover, preserving loop continuity for most control applications.\u003c\/p\u003e\n\u003cp\u003eQ: Are calibration parameters hardware‑defined or software‑configured? A: Resolution and electrical characteristics are hardware‑defined; mapping and scaling are configured through Experion PKS software.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain shield continuity for analog cabling to reduce induced noise from adjacent digital networks.\u003c\/li\u003e\n\u003cli\u003eSegregate 4–20 mA wiring from high‑energy AC conductors inside trays.\u003c\/li\u003e\n\u003cli\u003eVerify terminal torque to prevent micro‑movement under vibration.\u003c\/li\u003e\n\u003cli\u003eEnsure correct seating on CC‑TAOX or GAOX IOTA bases before energizing.\u003c\/li\u003e\n\u003cli\u003eAvoid tight bend radii to preserve conductor integrity and ripple performance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":40958937956426,"sku":"CC-PAOX01 51405039-275","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/8c.jpg?v=1712046647","url":"https:\/\/www.topbrandsplc.com\/products\/honeywell-c300-system-cc-paox01-51405039-275-analog-output-module","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}