{"product_id":"honeywell-dc-taox61-analog-output-input-output-termination-assembly","title":"Honeywell DC-TAOX61 Analog Output Input\/Output Termination Assembly","description":"\u003ch1\u003eHoneywell DC-TAOX61 Analog Output Input\/Output Termination Assembly\u003c\/h1\u003e\n\u003cp\u003eConfigured for high-integrity control signal distribution and 1:1 redundant analog output management in Experion PKS Series C architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell DC-TAOX61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eDC-TAOX61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output IOTA) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC-TAOX61\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell \/ Experion PKS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ Multi-Region\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg (1.87 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Series C IOTA form factor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Experion PKS Series C Architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels (Redundant 16-point configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA standard (software configurable to 0–20 mA or 0–24 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHART Communication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully supported (Pass-through for HART-enabled field devices)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Load Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e750 ohm at nominal 24 VDC loop voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC System Power \/ Backplane loop powered\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1:1 Redundant footprint (accepts dual Series C AO modules such as CC-TAOX61)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHazardous Area Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eII 3G Ex nA nC IIC T4 Gc (Zone 2 explosive environments)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e1:1 Redundancy Switching \u0026amp; 4-20 mA HART Loop Protocols\u003c\/h3\u003e\n\u003cp\u003eThe DC-TAOX61 IOTA provides a robust 1:1 redundant termination platform engineered to mount dual Series C analog output modules (such as CC-TAOX61). Integrated current-limiting circuitry and transient surge suppression on every channel terminal safeguard internal control electronics from field short-circuits and inductive voltage spikes. The assembly supports standard 4-20 mA outputs with transparent HART pass-through capabilities, ensuring uninterrupted control execution and continuous diagnostic data access for field actuators and positioners during active module failovers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What redundancy configuration is supported by the DC-TAOX61 Termination Assembly?\u003c\/p\u003e\n\u003cp\u003eA: The IOTA features a 1:1 redundant footprint that accepts dual Series C analog output modules to guarantee zero-process-interruption loop execution during failover events.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DC-TAOX61 IOTA support HART-enabled field instrumentation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit fully supports HART communication pass-through, allowing bi-directional digital diagnostic data transmission over standard 4-20 mA analog control loops.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum load resistance supported on the analog output channels?\u003c\/p\u003e\n\u003cp\u003eA: Each channel supports a maximum load resistance of up to 750 ohms when operating at nominal 24 VDC loop voltage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the DC-TAOX61 IOTA securely onto a standard Series C channel rail inside the control cabinet, verifying that the mechanical mounting latches lock firmly in place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate field actuator and control valve wiring to the plug-in screw or clamp terminals, ensuring correct polarity for 4-20 mA current loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute analog output signal cables through dedicated, grounded wire trays separated physically from high-voltage AC power and motor drive feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the main cabinet earth ground bar directly to the IOTA grounding lug using a low-impedance copper conductor to maintain transient surge suppression and Zone 2 safety compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67651711565898,"sku":"DC-TAOX61","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/DC-TAIL51_2.png?v=1758011075","url":"https:\/\/www.topbrandsplc.com\/products\/honeywell-dc-taox61-analog-output-input-output-termination-assembly","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}