{"product_id":"honeywell-fs-tsgas-1624-fail-safe-gas-flame-detector-input-fta","title":"Honeywell FS-TSGAS-1624 Fail-Safe Gas-Flame Detector Input FTA","description":"\u003ch2\u003eHoneywell FS-TSGAS-1624 Fail-Safe Gas-Flame Detector Input FTA\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFS-TSGAS-1624\u003c\/strong\u003e is a 16-channel fail-safe gas and flame detector input Field Termination Assembly (FTA) manufactured by Honeywell for safety instrumented systems. It connects field-mounted gas and flame detection transmitters directly to the safety system logic solver, providing secure signal conditioning and electrical termination for critical hazard monitoring loops.\u003c\/p\u003e\n\u003ch3\u003eInput Channel Configuration and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe FTA accommodates 16 analog input channels designed for standard 0–20 mA current signals referencing a common 0 V connection. Each channel incorporates a 500 Ω (±5%) input termination resistor that converts incoming field currents into a proportional 0–4 VDC signal routed to the corresponding SAI-1620m safety input module with high conversion precision (0.1% accuracy).\u003c\/p\u003e\n\u003ch3\u003ePower Distribution and Safety Certifications\u003c\/h3\u003e\n\u003cp\u003eOperating from an external 24 VDC power supply, the module exhibits a low baseline power draw of 3 mA (excluding field loop power requirements). Built for stringent functional safety and industrial regulatory compliance, the assembly carries major global safety certifications, including CE, TÜV, UL, CSA, and FM approvals.\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-TSGAS-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eField Termination Assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eGas-Flame Detector Input FTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Module Interface\u003c\/td\u003e\n\u003ctd\u003ePairs with SAI-1620m module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 analog inputs (0 to 20 mA, common 0 V reference)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e500 ohms +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e0 to 4 VDC (0.1% accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Current Draw\u003c\/td\u003e\n\u003ctd\u003e3 mA (without field loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL, CSA, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What safety input module does the FS-TSGAS-1624 pair with? A: The FS-TSGAS-1624 FTA routes conditioned 0–4 VDC signal outputs directly to the Honeywell SAI-1620m safety analog input module.\u003c\/p\u003e\n\u003cp\u003eQ: How does the FTA convert field current loops into voltage signals for the controller? A: Each of the 16 input channels uses an internal 500 Ω (±5%) resistor to convert 0–20 mA field transmitter signals into a 0–4 VDC analog input range.\u003c\/p\u003e\n\u003cp\u003eQ: What is the power consumption of the module itself? A: The FTA draws 3 mA from an external 24 VDC supply under nominal conditions, excluding additional current drawn by connected field loop devices.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67907784474698,"sku":"FS-TSGAS-1624","price":1000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/FS-PDB-CPX05_3_66a5c8cc-f01d-4268-882d-0f8e1da7e5b5.png?v=1793862842","url":"https:\/\/www.topbrandsplc.com\/products\/honeywell-fs-tsgas-1624-fail-safe-gas-flame-detector-input-fta","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}