{"product_id":"mtl5041-mtl-repeater-power-supply","title":"MTL5041 |  MTL  | Repeater Power Supply","description":"\u003ch2\u003eMTL MTL5041 Repeater Power Supply\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL5041 Repeater Power Supply\u003c\/strong\u003e is an intrinsically safe interface module designed to power conventional 2-wire 4-20 mA transmitters installed in hazardous areas while accurately repeating the signal to equipment located in the safe area. The module provides a fully floating DC supply, galvanic isolation, and high-accuracy signal transfer, making it suitable for process measurement applications requiring intrinsic safety compliance.\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMTL5041\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eMTL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRepeater Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eIntrinsically Safe Transmitter Power Supply and Signal Repeater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous-Area Input\u003c\/td\u003e\n\u003ctd\u003e0-24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e16.5 V at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe-Area Output\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (0-24 mA over\/under-range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Resistance\u003c\/td\u003e\n\u003ctd\u003e1 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e20-35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 20 uA at 20 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 uA\/deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 us to 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Support\u003c\/td\u003e\n\u003ctd\u003eZone 0, Division 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx, FM, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Isolation and Repetition\u003c\/h3\u003e\n\u003cp\u003eThe MTL5041 is designed to interface directly with conventional 2-wire transmitters located in hazardous areas. It supplies operating power to the field device and transfers the process signal to the safe area while maintaining the intrinsic safety barrier between the two environments.\u003c\/p\u003e\n\u003cp\u003eIts fully floating output architecture helps reduce ground loop issues and allows reliable signal transmission to control systems, recorders, indicators, or PLC analog input channels.\u003c\/p\u003e\n\u003ch3\u003eHazardous-Area Applications\u003c\/h3\u003e\n\u003cp\u003eThe module is intended for installation where field instruments are located in Zone 0 or Division 1 hazardous locations. By limiting the energy that can enter the hazardous area, the MTL5041 allows process transmitters to operate safely while maintaining measurement integrity.\u003c\/p\u003e\n\u003cp\u003eTypical field devices include pressure, temperature, level, and flow transmitters using the standard 4-20 mA process signal.\u003c\/p\u003e\n\u003ch3\u003eMeasurement Performance\u003c\/h3\u003e\n\u003cp\u003eThe transfer accuracy of less than 20 uA at 20 deg C ensures faithful reproduction of the transmitter signal. Temperature drift remains below 1 uA per degree Celsius, helping maintain measurement stability across changing ambient conditions.\u003c\/p\u003e\n\u003cp\u003eWith a response time of less than 250 us, the module can accurately follow rapid signal variations without introducing significant delay into the measurement loop.\u003c\/p\u003e\n\u003ch3\u003eSystem Integration\u003c\/h3\u003e\n\u003cp\u003eThe hazardous-area input accepts signals from 0 mA to 24 mA while simultaneously supplying 16.5 V to the transmitter at 20 mA. On the safe side, the module reproduces the signal as a standard 4-20 mA output capable of driving loads up to 1 kOhm.\u003c\/p\u003e\n\u003cp\u003eThis allows straightforward integration with DCS, PLC, SCADA, and process control systems that use standard analog current inputs.\u003c\/p\u003e\n\u003ch3\u003eEnvironmental and Compliance Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module is rated for operation from -20 deg C to +60 deg C and is certified for use in hazardous environments under multiple international approval schemes.\u003c\/p\u003e\n\u003cp\u003eAvailable approvals include ATEX, IECEx, FM, UL, and CSA certifications, supporting deployment across a wide range of industrial installations requiring intrinsic safety compliance.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary purpose of the MTL5041?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The MTL5041 powers a 2-wire 4-20 mA transmitter in a hazardous area and repeats the measured signal to a safe-area control system while maintaining intrinsic safety isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output signal does the module provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The safe-area output is a 4-20 mA signal with support for 0-24 mA over-range and under-range conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the MTL5041 be used with standard PLC or DCS analog inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module provides a standard 4-20 mA output suitable for most PLC, DCS, recorder, and process control system analog input channels, provided the load does not exceed 1 kOhm.\u003c\/p\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":67776886767690,"sku":"MTL5041","price":480.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/MTL5041_3.png?v=1792655809","url":"https:\/\/www.topbrandsplc.com\/products\/mtl5041-mtl-repeater-power-supply","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}