{"product_id":"s202-c10-2cds252001r0104-abb-miniature-circuit-breaker","title":"S202-C10 2CDS252001R0104 | ABB | Miniature Circuit Breaker","description":"\u003cmain class=\"container\"\u003e\n\u003cdiv class=\"top-control-bar\"\u003e\n\u003cdiv class=\"system-title\"\u003e\n\u003ch2\u003eABB S202-C10 2CDS252001R0104 Miniature Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB S202-C10 2CDS252001R0104\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eS202-C10\u003c\/strong\u003e miniature circuit breaker, operates as a two‑pole protective device for overload and short‑circuit management within low‑voltage AC\/DC distribution systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eS202-C10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.224 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e35 × 88 × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e-25 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003e4.2 W (2.1 W per pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCore Performance Indicators\u003c\/th\u003e\n\u003ctd\u003e2P, 10 A, C curve; 6 kA AC\/DC breaking capacity; thermal overload + electromechanical short‑circuit trip; dielectric withstand 2 kV; impulse withstand 4–6.2 kV; mechanical endurance 20000 cycles; electrical endurance 20000 AC cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licenses\u003c\/h3\u003e\n\u003cp\u003eWithin ABB’s System pro M compact S200 platform, the S202‑C10 integrates with modular busbar assemblies and supports:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O density scaling\u003c\/strong\u003e through compact 2‑module width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware flash compatibility\u003c\/strong\u003e at system level, unaffected by breaker mechanical trip units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks\u003c\/strong\u003e indirectly supported via upstream PLC\/DCS integration, ensuring predictable breaker status signaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus communication velocity licenses\u003c\/strong\u003e maintained by ABB’s modular backplane interconnects, minimizing propagation delay in multi‑breaker arrays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the S202‑C10 be hot‑swapped on a live DIN rail?\u003c\/strong\u003e A: No. Removal or insertion must be performed with the supply isolated to prevent arcing and mechanical damage to terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the rated short‑circuit breaking capacity?\u003c\/strong\u003e A: The breaker supports 6 kA at AC\/DC, with service breaking capacity up to 15 kA at 230 V AC depending on installation standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is contact position indicated?\u003c\/strong\u003e A: A mechanical indicator shows red for ON and green for OFF, independent of actuator toggle position.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount on DIN rail TH35‑15 or TH35‑7.5 per IEC 60715.\u003c\/li\u003e\n\u003cli\u003eMaintain wire stripping length of 12.5 mm for screw terminals.\u003c\/li\u003e\n\u003cli\u003eApply tightening torque of 2.8 N·m (Pozidriv 2 screwdriver recommended).\u003c\/li\u003e\n\u003cli\u003eEnsure conductor cross‑section matches specified ranges (0.75–35 mm² rigid, 0.75–25 mm² flexible).\u003c\/li\u003e\n\u003cli\u003eVerify insulation group II housing integrity before energizing.\u003c\/li\u003e\n\u003cli\u003eMaintain ambient operating range −25 to +55 deg C; storage −40 to +70 deg C.\u003c\/li\u003e\n\u003cli\u003eFor vibration environments, confirm breaker seating and busbar stability to avoid contact fatigue.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/main\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44030087626826,"sku":"S202-C10 2CDS252001R0104","price":540.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/S201-K16NA_1.png?v=1760605067","url":"https:\/\/www.topbrandsplc.com\/products\/s202-c10-2cds252001r0104-abb-miniature-circuit-breaker","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}