{"product_id":"sptps13tps-abb-turbine-protection-module","title":"SPTPS13TPS | ABB | Turbine Protection Module","description":"\u003ch2\u003eABB SPTPS13TPS Turbine Protection Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB SPTPS13TPS\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSPTPS13TPS\u003c\/strong\u003e Turbine Protection Module, serves as a rack-mounted protection and speed measurement unit for turbine overspeed detection and emergency trip execution within Symphony Plus and Harmony Rack systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eSPTPS13TPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eRack slot module, Harmony Rack compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temp\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule Type\u003c\/th\u003e\n\u003ctd\u003eTurbine Protection and Speed Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Signals\u003c\/th\u003e\n\u003ctd\u003eTriple redundant speed sensor inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoting Logic\u003c\/th\u003e\n\u003ctd\u003eHardware-level 2-of-3 overspeed trip logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse Time\u003c\/th\u003e\n\u003ctd\u003eMillisecond-level trip response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunctions\u003c\/th\u003e\n\u003ctd\u003eSpeed measurement, overspeed protection, acceleration monitoring, zero-speed detection, online logic test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eNatural convection or forced air via cabinet fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eStandard Harmony rack slot, hot-swappable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSIL3 Certification and Triple Modular Redundancy\u003c\/h3\u003e\n\u003cp\u003eThe SPTPS13TPS module is designed for high-reliability safety instrumented systems (SIS). It supports SIL3 certification requirements and employs triple modular redundancy (TMR) with 2oo3 voting architecture. This ensures fail-safe state execution during overspeed events, while maintaining deterministic trip response. Galvanic isolation between sensor inputs enhances signal integrity and prevents cross-channel interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the SPTPS13TPS module be hot-swapped during turbine operation? A: Yes. It supports hot-swapping in Harmony racks, but commissioning procedures must ensure trip logic integrity before re-energizing.\u003c\/p\u003e\n\u003cp\u003eQ: How is overspeed trip logic validated? A: Hardware-level 2-of-3 voting ensures that at least two sensor inputs confirm overspeed before trip execution.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support online testing? A: Yes. Overspeed protection circuits can be tested during normal turbine operation without interrupting functionality.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in designated Harmony rack slots with full connector engagement.\u003c\/li\u003e\n\u003cli\u003eEnsure triple redundant speed sensor wiring is shielded and routed separately to minimize induced noise.\u003c\/li\u003e\n\u003cli\u003eValidate 2oo3 voting logic during commissioning to confirm correct overspeed trip sequencing.\u003c\/li\u003e\n\u003cli\u003eMaintain cabinet cooling via natural convection or forced fan systems.\u003c\/li\u003e\n\u003cli\u003eConfirm environmental conditions meet system specifications before energizing.\u003c\/li\u003e\n\u003cli\u003ePerform online logic tests periodically to verify trip circuit integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44215094771786,"sku":"SPTPS13TPS","price":540.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/SPFEC12_2.png?v=1750925429","url":"https:\/\/www.topbrandsplc.com\/products\/sptps13tps-abb-turbine-protection-module","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}