{"product_id":"yokogawa-cp461-50-central-processing-unit","title":"Yokogawa | CP461-50 | Central Processing Unit","description":"\u003ch1\u003eYokogawa CP461-50 Processor Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for high-performance control execution in AFV300 and AFV400 CENTUM VP field control stations, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CP461-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eCP461-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcessor Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Series: CP461 Processor Module for AFV300 and AFV400 systems (direct replacement for the legacy CP461-10 module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuffix Code 5: Standard type with no explosion protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuffix Code 0: Basic functional type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundancy Configuration: Designed for dual-redundant deployment utilizing paired modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCP461-50\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOEM Specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7 kg (Shipping weight: 2.0 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.2 cm x 5.1 cm x 20.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial standard DCS envelope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowered via CENTUM control unit backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAFV300 and AFV400 Field Control Units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Non-standard I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 modules supported\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and DCS System Execution\u003c\/h3\u003e\n\u003cp\u003eThe processor module acts as the central intelligence for Yokogawa field control stations, orchestrating high-speed deterministic control and data acquisition across connected I\/O nodes. It manages process control loops, including standard 4-20 mA HART instrumentation signals and digital fieldbus communication packets. Designed to operate in a dual-redundant configuration with automatic switchover capabilities, the module ensures continuous, uninterrupted process execution and channel isolation across the backplane bus without triggering controller faults during failover events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which legacy processor model does the CP461-50 replace?\u003c\/p\u003e\n\u003cp\u003eA: The CP461-50 serves as an upgraded direct replacement for the earlier CP461-10 Processor Module.\u003c\/p\u003e\n\u003cp\u003eQ: How many modules are required for a redundant processor setup?\u003c\/p\u003e\n\u003cp\u003eA: A dual-redundant configuration requires two matching CP461-50 modules installed in the designated control unit slots.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum number of non-standard I\/O modules supported by the station?\u003c\/p\u003e\n\u003cp\u003eA: The processor architecture supports a maximum of 8 non-standard I\/O modules within the node configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure station power is completely de-energized before inserting or extracting the CP461-50 processor module from the control unit chassis backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that ambient cabinet operating temperatures align with standard industrial DCS environmental guidelines to prevent thermal throttling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the module card carefully along the chassis guide rails and secure the top and bottom retention fasteners to guarantee solid backplane connector engagement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm redundant pairing synchronization status via the system engineering station indicators immediately following initial power-up and commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":40853479129162,"sku":"CP461-50","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/CP461-10S1_2_6acf56af-2337-4b18-8888-c9abe91216e1.jpg?v=1710382701","url":"https:\/\/www.topbrandsplc.com\/products\/yokogawa-cp461-50-central-processing-unit","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}