{"product_id":"yokogawa-ys1700-030-programmable-indicating-controller","title":"Yokogawa YS1700-030 Programmable Indicating Controller","description":"\u003ch2\u003eYokogawa YS1700-030 Programmable Indicating Controller\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa YS1700-030\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eYS1700\u003c\/strong\u003e programmable indicating controller, is a dual-CPU single-loop process controller designed for robust industrial automation applications. The suffix \u003cstrong\u003e-030\u003c\/strong\u003e indicates a configuration with hard manual backup, compatibility with YS80 internal units, and a universal power supply.\u003c\/p\u003e\n\u003ch3\u003eHardware Identification Code Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-0\u003c\/strong\u003e: Equipped with a hard manual unit (independent circuit with manual control wheel for backup if both CPUs fail).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\u003c\/strong\u003e: Compatible type for YS80 internal unit \/ compatible with EBS, I, EK, and HOMAC cases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Standard universal power supply (100–240 V AC \/ 24–120 V DC).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eYS1700-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Loop Style\u003c\/th\u003e\n\u003ctd\u003eSingle-loop, Cascade, Selector control; supports custom programming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Architecture\u003c\/th\u003e\n\u003ctd\u003eDual-CPU (independent control and display processors for fail-safe redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMemory Architecture\u003c\/th\u003e\n\u003ctd\u003eNonvolatile flash memory (no battery\/capacitor backup required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay Type\u003c\/th\u003e\n\u003ctd\u003e3.5-inch full dot-matrix color TFT LCD, adjustable brightness, sunlight-readable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay Views\u003c\/th\u003e\n\u003ctd\u003eLoop display, Trend graphs, Bar charts, Alarms, Event history\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgramming Capacity\u003c\/th\u003e\n\u003ctd\u003eText-based: up to 1,000 steps; Function block GUI: up to 400 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCalculation Engine\u003c\/th\u003e\n\u003ctd\u003eIEEE754 4-byte floating-point calculations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalog Inputs\u003c\/th\u003e\n\u003ctd\u003e5 total (1–5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalog Outputs\u003c\/th\u003e\n\u003ctd\u003e2 total (1 × 4–20 mA DC, 1 × 1–5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDigital I\/O\u003c\/th\u003e\n\u003ctd\u003e6 configurable points (DI\/DO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eUniversal 100–240 V AC (±10%), 50\/60 Hz \/ 24–120 V DC (±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003eMax 30 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFaceplate Rating\u003c\/th\u003e\n\u003ctd\u003eIP54 dust-proof and splash-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e250 mm Depth × 162.4 mm Height × 60 mm Width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFunctional Highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-CPU redundancy\u003c\/strong\u003e ensures continuous operation even if one processor fails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHard manual unit\u003c\/strong\u003e allows operators to maintain loop control during CPU halt.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGraphical display\u003c\/strong\u003e provides real-time loop trends, alarms, and event history.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible programming\u003c\/strong\u003e supports both text-based and function block logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal power supply\u003c\/strong\u003e enables deployment across diverse industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount controller in DIN-standard flush panel cutouts with gasket sealing.\u003c\/li\u003e\n\u003cli\u003eSegregate analog signal wiring from digital outputs to reduce interference.\u003c\/li\u003e\n\u003cli\u003eProvide stable power supply within specified ranges (100–240 V AC \/ 24–120 V DC).\u003c\/li\u003e\n\u003cli\u003eVerify grounding continuity for shielding layers to minimize EMI.\u003c\/li\u003e\n\u003cli\u003eConfirm ambient temperature remains within -20 °C to +70 °C for reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44171621761098,"sku":"YS1700-030","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/8569\/3770\/files\/YS1700-101_1.png?v=1763704451","url":"https:\/\/www.topbrandsplc.com\/products\/yokogawa-ys1700-030-programmable-indicating-controller","provider":"Topbrands PLC Limited","version":"1.0","type":"link"}