Triconex 8120E Enhanced Performance Main Chassis
Configured for high-integrity Safety Instrumented Systems (SIS), the Triconex 8120E (8120E Enhanced Performance Main Chassis) provides direct physical/electrical execution. The 19-slot chassis hardware houses three main processors and integrated I/O modules, maintaining continuous diagnostic coverage across emergency shutdown (ESD) and critical safety loops.
Hardware Specifications
| Parameter |
Specification |
| Model |
8120E |
| Brand |
Triconex |
| Origin |
USA |
| Weight |
24.5 kg |
| Dimensions |
483 mm wide x 578 mm high (19-inch rack mount) |
| Operating Temp |
-20 deg C to +70 deg C |
| Power Consumption |
Dual redundant 24 VDC (20-30 VDC range) or 100-240 VAC (50/60 Hz) |
| System Capacity |
19 modular card slots |
| Ingress Protection |
IP30 (intended for indoor cabinet mounting) |
| Backplane Bus |
1000 Mbps TriBus inter-processor bus; triple RS-485 I/O bus |
| Isolation |
Galvanic isolation across internal distribution rails (5 VDC / 24 VDC) |
SIL3 Certification & Triple Modular Redundancy (TMR) Architecture
The 8120E chassis provides the hardware foundation for SIL3-certified triple modular redundancy (TMR) applications. Three isolated power, logic, and bus channels run concurrently across the backplane, allowing the host system to execute 2oo3 (two-out-of-three) voting logic on all input signals and internal diagnostic states. Internal galvanic isolation barriers separate the field power lines from central processing buses, ensuring that single-point electrical faults or channel failures trigger immediate fail-safe state execution without causing system-wide shutdown.
Frequently Asked Questions
Q: How does the 8120E chassis backplane maintain fault isolation during module failure?
A: The backplane features three completely separated signal and power distribution channels. Galvanic isolation and fault-tolerant TriBus architecture prevent an electrical short or hardware failure on one channel from propagating to the remaining two active channels.
Q: Can modules installed in the 8120E chassis be replaced while power is applied?
A: Yes, the chassis supports full hot-swap capability for main processors, communication modules, and I/O cards, allowing online module replacement without de-energizing the safety system or disrupting active 2oo3 voting loops.
Field Installation Guidelines
-
Mount the 8120E chassis securely into a standard 19-inch industrial rack enclosure, ensuring proper structural support for its 24.5 kg frame weight.
-
Connect dual redundant 24 VDC or 100-240 VAC power feeds to the chassis power terminal connections to maintain continuous power path fault tolerance.
-
Maintain adequate vertical ventilation space inside the cabinet to facilitate natural convection heat dissipation across installed modules.
-
Bond the chassis ground lug directly to the central functional earth bar with a low-impedance copper conductor to prevent electromagnetic noise coupling onto backplane bus lines.
Topbrands PLC Limited is a top supplier of genuine new PLC and DCS parts, serving over 50 countries globally. We offer high-quality products from renowned brands like Bently Nevada, Honeywell, ABB, and more. With our warehouse in China stocking up to 30,000 pieces, we ensure rapid delivery to meet urgent order needs while maintaining competitive pricing to save our customers' budgets. Learn more...