Allen-Bradley 140M-C2E-C10 Motor Protection Circuit Breaker
The Allen-Bradley 140M-C2E-C10, also cataloged as the 140M-C2E-C10 Motor Protection Circuit Breaker, operates as a dedicated hardware component for motor branch circuit protection within industrial motor control systems. The device combines adjustable thermal overload protection and fixed magnetic short-circuit protection in a compact three-pole enclosure.
Hardware Specifications
| Parameter |
Specification |
| Model |
140M-C2E-C10 |
| Brand |
Allen-Bradley |
| Origin |
USA |
| Weight |
0.32 kg |
| Dimensions |
90 mm x 45 mm x 74.5 mm |
| Operating Temp |
-25 deg C to +60 deg C |
| Power Consumption |
Not applicable |
| Product Type |
Motor Protection Circuit Breaker |
| Current Adjustment Range |
6.3 A to 10.0 A |
| Magnetic Trip Current |
130 A Fixed |
| Rated Operational Voltage |
Up to 690 V AC |
| Rated Insulation Voltage |
690 V AC |
| Rated Impulse Withstand Voltage |
6 kV |
| Trip Class |
Class 10 |
| Number of Poles |
3 |
| Breaking Capacity at 400/415 V AC |
100 kA |
| Maximum Motor Rating at 460 V AC |
7.5 HP |
| Maximum Motor Rating at 690 V AC |
7.5 kW |
| Protection Class |
IP2X |
| Control Mechanism |
Rotary Turn Button |
| Mechanical / Electrical Life |
100,000 Operations |
| Storage Temperature |
-40 deg C to +80 deg C |
| Maximum Installation Altitude |
2000 m |
Motor Protection and Backplane Control Integration
The 140M-C2E-C10 combines thermal and magnetic tripping functions for motor feeder protection. The adjustable thermal setting allows alignment with motor full-load current requirements, while the fixed magnetic trip threshold provides short-circuit protection. The device can be integrated with motor starters, contactors, and PLC-based motor control architectures.
Frequently Asked Questions
Q: What motor current range can be adjusted on this breaker?
A: The thermal overload adjustment range is 6.3 A to 10.0 A.
Q: What magnetic trip level is provided?
A: The breaker includes a fixed magnetic trip setting of 130 A.
Q: How many poles are included in the device?
A: The 140M-C2E-C10 is a 3-pole motor protection circuit breaker.
Field Installation Guidelines
-
Mount the breaker inside a suitable motor control panel or enclosure.
-
Adjust the thermal setting to match the motor full-load current rating.
-
Verify all power conductors are terminated securely at the screw terminals.
-
Connect protective earth conductors according to applicable electrical standards.
-
Maintain separation between power wiring and low-level control circuits.
-
Verify short-circuit coordination requirements before commissioning.
-
Inspect terminal tightness periodically during preventive maintenance.
Topbrands PLC Limited is a top supplier of genuine new PLC and DCS parts, serving over 50 countries globally. We offer high-quality products from renowned brands like Bently Nevada, Honeywell, ABB, and more. With our warehouse in China stocking up to 30,000 pieces, we ensure rapid delivery to meet urgent order needs while maintaining competitive pricing to save our customers' budgets. Learn more...