Allen-Bradley 1492-H4 Fuse Terminal Block
Configured for circuit protection and fused field wiring distribution in Allen-Bradley control panels, the Allen-Bradley 1492-H4 (1492-H4 Fuse Terminal Block) provides direct electrical termination and overcurrent protection within DIN rail-mounted control architectures. The terminal block incorporates a single fused circuit design with integrated blown-fuse indication and finger-safe construction for panel-level wiring applications.
Hardware Specifications
| Parameter |
Specification |
| Model |
1492-H4 |
| Brand |
Allen-Bradley |
| Product Type |
Fuse Terminal Block |
| Series |
1492 H-Block |
| Circuit Configuration |
Single-circuit fused terminal block |
| Current Rating |
15 A |
| Voltage Rating |
300 VAC/DC |
| Wire Range (UL/CSA) |
#30 AWG to #12 AWG |
| Wire Range (General) |
#30 AWG to #10 AWG |
| IEC Conductor Range |
0.5 mm2 to 4 mm2 |
| Fuse Indicator |
Integrated neon blown-fuse indicator |
| Mounting |
DIN rail |
| Color |
Black |
| Dimensions |
9.1 mm x 81.3 mm x 47 mm |
| Operating Temp |
-40 deg C to 105 deg C |
| Certifications |
CCC, CE, CSA, KC, UL |
DIN Rail Mounting Stability and Circuit Protection
The 1492-H4 is designed for installation on standard DIN rail assemblies used throughout industrial control cabinets. Mechanical retention on the rail assists in maintaining terminal positioning during normal equipment vibration and maintenance activities.
The integrated fuse holder provides localized branch circuit protection, allowing fault isolation without disturbing adjacent wiring. A built-in neon indicator provides visual confirmation of blown fuse conditions, supporting troubleshooting and maintenance procedures within energized control panels when permitted by site safety practices.
Frequently Asked Questions
Q: What type of circuit protection does the 1492-H4 provide?
A: The terminal block provides single-circuit fused protection through an integrated fuse holder design.
Q: How is a blown fuse identified?
A: The terminal block incorporates a built-in neon blown-fuse indicator for visual status identification.
Q: Is the terminal block suitable for DIN rail installation?
A: Yes. The 1492-H4 is designed specifically for DIN rail mounting within industrial control panels.
Field Installation Guidelines
-
Mount the terminal block securely onto a compatible DIN rail before connecting conductors.
-
Verify the installed fuse rating matches the circuit protection requirements.
-
Use conductors within the specified wire size range.
-
Tighten field wiring terminals according to applicable installation standards and manufacturer practices.
-
Maintain separation between power and low-level signal wiring where practical.
-
Inspect fuse clips periodically for signs of corrosion, overheating, or mechanical wear.
-
Confirm blown-fuse indicator operation during maintenance inspections.
-
Do not exceed the specified 15 A current rating or 300 VAC/DC voltage rating.
Topbrands PLC Limited is a top supplier of genuine new PLC and DCS parts, serving over 50 countries globally. We offer high-quality products from renowned brands like Bently Nevada, Honeywell, ABB, and more. With our warehouse in China stocking up to 30,000 pieces, we ensure rapid delivery to meet urgent order needs while maintaining competitive pricing to save our customers' budgets. Learn more...