Bently Nevada 330171-00-22-10-11-05 3300 5 mm Proximity Probe
The Bently Nevada 330171-00-22-10-11-05, also cataloged as the 330171 Proximity Probe, serves as the primary 5 mm eddy-current probe utilized to execute displacement measurement across 3300 series monitoring platforms.
Suffix Breakdown & Model Matrix
- 330171: 3300 5 mm Proximity Probe, 1/4-28 UNF thread, without armor
- -00: Unthreaded length option (0.0 inches)
- -22: Overall case length option (2.2 inches)
- -10: Integral cable length (1.0 meter / 3.3 feet)
- -11: Miniature coaxial ClickLoc connector with protector and FluidLoc cable
- -05: Agency approval option (multiple hazardous area certifications)
Hardware Specifications
| Parameter |
Specification |
| Model |
330171-00-22-10-11-05 |
| Brand |
Bently Nevada |
| Origin |
USA |
| Weight |
Not specified |
| Dimensions |
Case length 2.2 in |
| Operating Temp |
-35 to +177 deg C |
| Power Consumption |
Passive probe, powered via Proximitor |
| Thread Size |
1/4-28 UNF |
| Tip Material |
Polyphenylene sulfide (PPS) |
| Case Material |
AISI 304 stainless steel |
| Cable Length |
1.0 m integral |
| Connector |
Miniature coaxial ClickLoc with FluidLoc |
| Agency Approvals |
Multiple hazardous area certifications |
| Primary Use |
Fluid-film bearing machines, restricted installations |
Eddy-Current Probe Scaling
The 330171 probe employs eddy-current scaling to translate physical displacement into voltage signals. Calibration is standardized with -10 VDC gap voltage references, ensuring linearity across the 5 mm measurement range. This scaling supports rotor dynamics analysis and minimizes cross-talk when multiple probes are installed in confined geometries.
Frequently Asked Questions
Q: Can the 330171 probe be directly connected to a 3300 XL Proximitor? A: No, the 3300 5 mm probe requires its designated 3300 Proximitor; XL variants are not interchangeable.
Q: What is the recommended grounding practice for the FluidLoc cable? A: Shielding should be grounded at the Proximitor end only to prevent ground loop currents.
Q: How does the stainless steel case material affect installation? A: AISI 304 stainless steel provides mechanical durability and corrosion resistance, suitable for harsh industrial environments.
Field Installation Guidelines
- Engage 1/4-28 UNF threads with at least 5 turns for secure seating.
- Route integral cable separately from high-voltage conductors to minimize induced noise.
- Ground shielding only at the Proximitor termination.
- Verify -10 VDC gap voltage calibration during commissioning.
- Maintain probe tip cleanliness; PPS material must not be exposed to abrasive contaminants.
Topbrands PLC Limited is a top supplier of genuine new PLC and DCS parts, serving over 50 countries globally. We offer high-quality products from renowned brands like Bently Nevada, Honeywell, ABB, and more. With our warehouse in China stocking up to 30,000 pieces, we ensure rapid delivery to meet urgent order needs while maintaining competitive pricing to save our customers' budgets. Learn more...