Emerson EPRO PR9376/010-011 Hall Effect Speed/Proximity Sensor
Configured for rotational speed detection and proximity monitoring in machinery protection systems, the Emerson EPRO PR9376/010-011 (PR9376 Hall Effect Speed/Proximity Sensor) provides direct non-contact pulse generation from rotating targets and metallic reference markers. The sensor utilizes Hall effect technology to produce speed and phase-reference signals for turbine, compressor, pump, and generator monitoring systems.
Hardware Specifications
| Parameter |
Specification |
| Model |
PR9376/010-011 |
| Brand |
Emerson EPRO |
| Product Type |
Hall Effect Speed/Proximity Sensor |
| Sensing Technology |
Non-contact Hall Effect |
| Cable Construction |
Armored Cable |
| Cable Length |
5 m |
| Cable Termination |
Open Cable End |
| Supply Voltage |
10 VDC to 30 VDC |
| Maximum Operating Frequency |
12 kHz (720,000 cpm) |
| Response Time |
1 us |
| Housing Material |
Stainless Steel |
| Cable Material |
PTFE |
| Protection Class |
IP67 |
| Operating Temp |
-25 deg C to +100 deg C |
| Weight |
Approximately 210 g |
| Origin |
Germany |
Speed Pulse Integrity and Rotating Machinery Monitoring
The PR9376 is designed to generate discrete speed pulses from ferromagnetic targets moving through the sensor's magnetic field. The Hall effect sensing principle allows speed measurement from zero speed through high-frequency operating ranges without physical contact between the sensor and rotating equipment.
In turbine and compressor monitoring systems, the sensor is commonly used for rotational speed measurement, overspeed protection inputs, phase reference generation, and keyphasor-related timing functions. Signal quality is dependent upon target geometry, installation gap, cable integrity, and electromagnetic noise control within the field installation.
Frequently Asked Questions
Q: Can the PR9376 operate at zero rotational speed?
A: Yes. Hall effect sensors can detect static target presence and are suitable for low-speed and zero-speed detection applications unlike some passive magnetic pickup technologies.
Q: What cable configuration is supplied with the PR9376/010-011 version?
A: This configuration is supplied with a 5 m armored cable and open cable end termination.
Q: What is the maximum input frequency the sensor can process?
A: The specified maximum operating frequency is 12 kHz, equivalent to 720,000 cpm.
Field Installation Guidelines
-
Install the sensor with an appropriate target gap according to the machinery protection system requirements.
-
Route sensor wiring separately from motor feeders, VFD output cables, and high-current conductors.
-
Protect armored cable sections from excessive bending and mechanical stress.
-
Maintain shield continuity and grounding practices consistent with plant instrumentation standards.
-
Verify supply voltage remains within the specified 10 VDC to 30 VDC operating range.
-
Confirm pulse output quality during commissioning across the expected machine speed range.
-
Inspect sensor mounting hardware periodically for loosening caused by machine vibration.
-
Verify IP67 sealing integrity if the sensor is installed in wet or contaminated environments.
Topbrands PLC Limited is a top supplier of genuine new PLC and DCS parts, serving over 50 countries globally. We offer high-quality products from renowned brands like Bently Nevada, Honeywell, ABB, and more. With our warehouse in China stocking up to 30,000 pieces, we ensure rapid delivery to meet urgent order needs while maintaining competitive pricing to save our customers' budgets. Learn more...
Contact Information