Emerson Epro PR6423/000-031-CN 8mm Eddy Current Sensor
The Emerson Epro PR6423/000-031-CN, also cataloged as the PR6423/000-031-CN 8mm Eddy Current Sensor, operates as a dedicated hardware component for non-contact shaft vibration and displacement measurement within machinery protection platforms. The high-frequency eddy-current sensing element observes dynamic physical position changes between the probe tip and a conductive target surface without mechanical contact.
Hardware Specifications
| Parameter |
Specification |
| Model |
PR6423/000-031-CN |
| Brand |
Emerson Epro |
| Origin |
Germany |
| Weight |
0.5 kg |
| Dimensions |
M10 x 1 threaded housing |
| Operating Temp |
Sensor Tip & Cable: -35 deg C to +180 deg C (up to +200 deg C peak) |
| Power Consumption |
Powered via connected signal converter / signal conditioner (-24 VDC loop) |
| Linear Range |
0 to 2 mm (80 mils) |
| Initial Gap Offset |
0.5 mm (20 mils) nominal |
| Incremental Scale Factor |
8 V/mm (approx 203.2 mV/mil) |
| Sensing Technology |
Non-contact eddy current |
Mechanical Monitoring & Eddy-Current Probe Scaling
The PR6423/000-031-CN eddy current sensor operates across a linear measuring span of 0 to 2 mm (80 mils) with an Incremental Scale Factor (ISF) of 8 V/mm (203.2 mV/mil). Installation validation requires setting the static initial gap voltage offset to approximately 0.5 mm (20 mils), corresponding to the calibrated midpoint of the signal range. The probe tip driver minimizes cross-talk suppression issues when sensors are mounted in orthogonal 90-deg configurations, maintaining signal accuracy for high-speed rotor dynamics and axial thrust position tracking.
Frequently Asked Questions
Q: What is the calibrated sensitivity factor for the PR6423/000-031-CN probe system?
A: The sensor provides an Incremental Scale Factor (ISF) of 8 V/mm (approximately 203.2 mV/mil) over its 0 to 2 mm linear measuring span when used with a calibrated signal converter.
Q: What temperature limits apply to the sensor probe tip and integrated cable?
A: The probe head and attached cable withstand continuous operating temperatures ranging from -35 deg C to +180 deg C (with peak short-term capability up to +200 deg C).
Field Installation Guidelines
-
Maintain a minimum physical distance between adjacent sensor tips to prevent mutual inductive coupling and signal cross-talk.
-
Thread the M10 x 1 housing into the mounting bracket while measuring the DC gap voltage to set the nominal 0.5 mm physical offset.
-
Protect the sensor cable run using flexible metal conduit or internal armor, avoiding sharp bends that exceed the minimum bend radius.
-
Ensure the sensor housing maintains solid mechanical earth grounding while keeping the signal cable shield isolated from intermediate conduit enclosures.
Topbrands PLC Limited is a top supplier of genuine new PLC and DCS parts, serving over 50 countries globally. We offer high-quality products from renowned brands like Bently Nevada, Honeywell, ABB, and more. With our warehouse in China stocking up to 30,000 pieces, we ensure rapid delivery to meet urgent order needs while maintaining competitive pricing to save our customers' budgets. Learn more...