HIMA F3313 Digital Input Module
The HIMA F 3313 serves as the primary F 3313 Digital Input Module utilized to execute safety signal acquisition across HIMA HiQuad safety controller platforms. The module receives discrete field-state signals and transfers validated input status information to the safety processor for logic execution and fail-safe monitoring functions.
Hardware Specifications
| Parameter |
Specification |
| Model |
F 3313 |
| Brand |
HIMA |
| Product Type |
Digital Input Module |
| System Platform |
HiQuad Safety System |
| Safety Integrity Level |
SIL 3 |
| Safety Standard |
IEC 61508 |
| Performance Level |
PL e |
| Supply Voltage |
24 VDC (+/-15%) |
| Response Time |
< 15 ms |
| Operating Temp |
-25 deg C to +60 deg C |
| Weight |
Approximately 0.4 kg |
| Origin |
Germany |
| HS Code |
85389091 |
| Signal Type |
Digital safety inputs |
| Application |
Safety monitoring and interlock systems |
SIL 3 Safety Architecture
The F3313 is designed for integration into HIMA functional safety systems requiring high-integrity signal processing. The module supports SIL 3 safety applications in accordance with IEC 61508 requirements and is intended for safety-related monitoring tasks.
Input states received from field devices are processed within the HIMA safety architecture and transferred to the associated controller for execution of safety logic. The module is intended for applications requiring deterministic detection of field signal changes and fail-safe response handling.
The safety design supports implementation within architectures requiring Performance Level e (PL e) functional safety classification.
Fail-Safe Signal Acquisition and Galvanic Isolation
The module acquires discrete safety signals generated by field devices such as emergency stop stations, safety interlock switches, limit contacts, and protective sensing equipment.
Within the safety controller architecture, input signal validation assists in detecting operational state changes and supporting execution of configured safety functions. Proper wiring practices and signal separation methods help maintain signal quality and reduce the influence of electrical interference on safety-related input channels.
When integrated into HiQuad systems, the module becomes part of the overall fail-safe execution path responsible for initiating protective actions when required operating conditions are no longer satisfied.
Frequently Asked Questions
Q: What safety rating is supported by the F3313 module?
A: The module supports SIL 3 applications in accordance with IEC 61508 and supports PL e safety requirements.
Q: What supply voltage is required for operation?
A: The specified operating supply is 24 VDC with a tolerance of +/-15%.
Q: What types of field devices are commonly connected to the module?
A: Typical devices include emergency stop contacts, safety gate switches, interlock contacts, and other discrete safety-related input devices.
Field Installation Guidelines
-
Verify compatibility with the installed HiQuad controller architecture before installation.
-
Ensure the external power supply remains within the specified 24 VDC tolerance range.
-
Route safety input wiring separately from high-current AC and DC power conductors.
-
Use shielded wiring where required by site electrical design standards.
-
Confirm polarity and terminal assignment before energizing the module.
-
Perform input channel verification and safety function testing after installation.
-
Validate controller diagnostics and signal status before placing the safety function into service.
Topbrands PLC Limited is a top supplier of genuine new PLC and DCS parts, serving over 50 countries globally. We offer high-quality products from renowned brands like Bently Nevada, Honeywell, ABB, and more. With our warehouse in China stocking up to 30,000 pieces, we ensure rapid delivery to meet urgent order needs while maintaining competitive pricing to save our customers' budgets. Learn more...